Browsing by Subject "Partial least-squares regression"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Publication Application of two-dimensional fluorescence spectroscopy for the on-line monitoring of teff-based substrate fermentation inoculated with certain probiotic bacteria(2022) Alemneh, Sendeku Takele; Emire, Shimelis Admassu; Jekle, Mario; Paquet-Durand, Olivier; von Wrochem, Almut; Hitzmann, BerndThere is increasing demand for cereal-based probiotic fermented beverages as an alternative to dairy-based products due to their limitations. However, analyzing and monitoring the fermentation process is usually time consuming, costly, and labor intensive. This research therefore aims to apply two-dimensional (2D)-fluorescence spectroscopy coupled with partial least-squares regression (PLSR) and artificial neural networks (ANN) for the on-line quantitative analysis of cell growth and concentrations of lactic acid and glucose during the fermentation of a teff-based substrate. This substrate was inoculated with mixed strains of Lactiplantibacillus plantarum A6 (LPA6) and Lacticaseibacillus rhamnosus GG (LCGG). The fermentation was performed under two different conditions: condition 1 (7 g/100 mL substrate inoculated with 6 log cfu/mL) and condition 2 (4 g/100 mL substrate inoculated with 6 log cfu/mL). For the prediction of LPA6 and LCGG cell growth, the relative root mean square error of prediction (pRMSEP) was measured between 2.5 and 4.5%. The highest pRMSEP (4.5%) was observed for the prediction of LPA6 cell growth under condition 2 using ANN, but the lowest pRMSEP (2.5%) was observed for the prediction of LCGG cell growth under condition 1 with ANN. A slightly more accurate prediction was found with ANN under condition 1. However, under condition 2, a superior prediction was observed with PLSR as compared to ANN. Moreover, for the prediction of lactic acid concentration, the observed values of pRMSEP were 7.6 and 7.7% using PLSR and ANN, respectively. The highest error rates of 13 and 14% were observed for the prediction of glucose concentration using PLSR and ANN, respectively. Most of the predicted values had a coefficient of determination (R2) of more than 0.85. In conclusion, a 2D-fluorescence spectroscopy combined with PLSR and ANN can be used to accurately monitor LPA6 and LCGG cell counts and lactic acid concentration in the fermentation process of a teff-based substrate. The prediction of glucose concentration, however, showed a rather high error rate.Publication Non-destructive near-infrared technology for efficient cannabinoid analysis in cannabis inflorescences(2024) Rafiq, Hamza; Hartung, Jens; Schober, Torsten; Vogt, Maximilian M.; Carrera, Dániel Árpád; Ruckle, Michael; Graeff-Hönninger, SimoneIn the evolving field of cannabis research, scholars are exploring innovative methods to quantify cannabinoids rapidly and non-destructively. This study evaluates the effectiveness of a hand-held near-infrared (NIR) device for quantifying total cannabidiol (total CBD), total delta-9-tetrahydrocannabinol (total THC), and total cannabigerol (total CBG) in whole cannabis inflorescences. Employing pre-processing techniques, including standard normal variate (SNV) and Savitzky–Golay (SG) smoothing, we aim to optimize the portable NIR technology for rapid and non-destructive cannabinoid analysis. A partial least-squares regression (PLSR) model was utilized to predict cannabinoid concentration based on NIR spectra. The results indicated that SNV pre-processing exhibited superior performance in predicting total CBD concentration, yielding the lowest root mean square error of prediction (RMSEP) of 2.228 and the highest coefficient of determination for prediction (R2P) of 0.792. The ratio of performance to deviation (RPD) for total CBD was highest (2.195) with SNV. In contrast, raw data exhibited the least accurate predictions for total THC, with an R2P of 0.812, an RPD of 2.306, and an RMSEP of 1.651. Notably, total CBG prediction showed unique characteristics, with raw data yielding the highest R2P of 0.806. SNV pre-processing emerges as a robust method for precise total CBD quantification, offering valuable insights into the optimization of a hand-held NIR device for the rapid and non-destructive analysis of cannabinoid in whole inflorescence samples. These findings contribute to ongoing efforts in developing portable and efficient technologies for cannabinoid analysis, addressing the increasing demand for quick and accurate assessment methods in cannabis cultivation, pharmaceuticals, and regulatory compliance.