Bitte beachten Sie: Im Zeitraum vom 21.12.2024 bis zum 07.01.2025 werden auf hohPublica keine Anfragen oder Publikationen durch das KIM bearbeitet. Please note: KIM will not process any requests or publications on hohPublica between December 21, 2024 and January 7, 2025.
 

A new version of this entry is available:

Loading...
Thumbnail Image
Article
2002

Measurements and Modelling of Full-Scale Concentration Fluctuations : Open-field experiments using krypton-85 and tetrahydrothiophen as tracers

Abstract (English)

The simulation of odour frequencies near animal housing facilities or industrial plants requires a model of the frequency distribution of con- centration. Generally, for this purpose two-parameter distribution func- tions are used, which, depending upon the mean value and the variance of odour concentration, provide information about the probability of oc- currence. In order to examine how well the simulations coincide with reality, the calculation results are compared with measurement data. In model construction this examination step is also termed validation. Open-field experiments with tracers serve to examine the dispersion and fluctuation behaviour of airborne material in the atmospheric wind field. If in particular one intends to analyze the concentration fluctuations of odours, measuring techniques with high temporal resolution must be employed because odours can be perceived by the human nose within one second. In this examination, the artificially produced gas krypton-85 ser- ves as a tracer, whose concentration was measured by a group of detec- tors each at different distances from the source in one-second intervals. Based on the measurement data, mean values, variance, and higher sta- tistical moments of the tracer concentration are calculated and compared with the corresponding results of model simulations. Observed and simu- lated exceedance probabilities are compared, and the statistical charac- teristics of the models used are discussed. Do the results of the tracer measurement can be directly applied to odour frequencies? In order to answer this question, in some field experiments, the odourant tetrahydrothiophen, whose odour effects were registered by test persons at selected detector positions, was released at the same time as the tracer krypton-85. In contrast to the precise, unambiguous tracer measurement, the perception and assessment of odours is dependent u- pon sensation so that the application of the exceedance probability de- termined through measurement to the frequency of sensory perception needs to be statistically validated.

File is subject to an embargo until

This is a correction to:

A correction to this entry is available:

This is a new version of:

Notes

Publication license

Publication series

Published in

Agrartechnische Forschung, 8 (2002), 1. ISSN: 0948-7298
Faculty
Faculty of Agricultural Sciences
Institute
Institute of Agricultural Engineering

Examination date

Supervisor

Edition / version

Citation

DOI

ISSN

ISBN

Language
English

Publisher

Publisher place

Classification (DDC)

Free keywords

Standardized keywords (GND)

Sustainable Development Goals

BibTeX

@article{Lung2002, url = {https://hohpublica.uni-hohenheim.de/handle/123456789/10464}, author = {Lung, Thomas and Müller, Hans-Joachim and Gläser, Manfred et al.}, title = {Measurements and Modelling of Full-Scale Concentration Fluctuations : Open-field experiments using krypton-85 and tetrahydrothiophen as tracers}, journal = {Agrartechnische Forschung}, year = {2002}, volume = {8}, number = {1}, }
Share this publication